 2-Wire Low-Profile Duct Smoke Detector
A Division of Pittway 3825 Ohio Avenue, St. Charles, IL 60174 1-800-SENSOR2 (736-7672), Fax 630-377-6495 http://www.systemsensor.com
Models Available
DH100I 2-wire Ionization Detector DH100P 2-wire Photoelectronic Detector
Features
* * * * * * * * * * Outside mounting tabs Telescoping sampling tube* Built-in reset button Easy to clean 12/24 VDC operation Ion or photo models available Remote test station option Air velocity rating from 500 to 4000 FPM Remote annunciator option Easy and quick mounting to round or rectangular ducts from 1-12 wide * Textured cover for convenient visual inspection * UL 268A listed * 3-year warranty System Sensor DH100 2-wire duct smoke detector is available as either an ionization or photoelectric model. This new design allows for simplified cleaning and maintenance, or a change in application without removing the duct housing. The DH100 samples air currents passing through a duct and gives dependable performance for management of fans, blowers, and air conditioning systems, preventing the spread of toxic smoke and fire gases through the protected area. WARNING: Duct smoke detectors have specific limitations. DUCT DETECTORS ARE: NOT a substitute for an open area smoke detector, NOT a substitute for early warning detection, and NOT a replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional duct detector application information.
Specifications
Length: Width: Depth: Shipping Weight: Operating Temperature Range: 143/8 inches (37 cm.) 51/2 inches (14 cm.) 23/4 inches (7 cm.) 3.75 lbs. (1.7 kg.) 23 to 131 F (-5 to 55 C) Operating Humidity Range: Air Duct Velocity: 10% to 93% relative humidity 500 to 4000 ft./min.
*Patent pending
(c) System Sensor 1/98 This document is not intended to be used for installation purposes. A05-976-00
Architectural/Engineering Specifications
The air duct smoke detector shall be a System Sensor Model DH100 Series Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The detector shall operate at air velocities of 500 feet per minute to 4000 feet per minute. It shall be capable of local testing via magnetic switch or remote testing using the RTS451KEY Remote Test Station. The unit shall be reset by local reset button or RTS451KEY. The duct detector housing shall incorporate an airtight smoke chamber in compliance with UL 268A, Standard for Smoke Detectors for Duct Applications. The housing shall be capable of mounting to either rectangular or round ducts without adapter brackets. An integral filter system shall be included to reduce dust and residue effects on detector and housing, thereby reducing maintenance and servicing. Sampling tubes shall either be telescoping or be easily installed after the housing is mounted to the duct by passing through the duct housing. The enlosure shall meet all applicable NEC and NFPA standards regarding electrical junction boxes. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring.
Electrical Ratings - DH100 (Includes Detector)
System Voltage: Ripple Voltage: Start-up Capacitance: Standby Ratings: 12/24 VDC 4 Volts peak to peak 0.02 F maximum 8.5 VDC minimum 35 VDC maximum 120 A maximum 4.2 VDC minimum at 10mA 6.6 VDC maximum at 100mA Alarm current must be limited to 100mA or less by the control panel. If used, the RA400Z remote lamp operates within the specified alarm currents. 2.50 VDC minimum 0.3 Sec. maximum 34.0 Sec. maximum
Alarm Ratings:
Reset Voltage: Reset Time: Start-up Time:
Page 2
A05-976-00
DH100 Wiring Guide
UL LISTED COMPATIBLE 2-WIRE CONTROL PANEL 1ST DETECTOR IN LOOP DH100 SUPERVISORY SWITCH 7 6 (+) (+) IN 4 ALARM INITIATION LOOP (+) OUT (+) (+) (-) (-) 2.8 VDC NOM. IN ALARM RA400Z (OPTIONAL) REMOTE ALARM LED 5 (+) IN 4 (+) OUT (+) (+) (-) (-) RA400Z (OPTIONAL) E REMOTE ALARM LED O L R 2.8 VDC NOM. IN ALARM LAST DETECTOR IN LOOP DH100 SUPERVISORY SWITCH 7 6 EOL RESISTOR SPECIFIED BY PANEL MANUFACTURER
5
(-)
8 (-) IN
(-) OUT
8 (-) IN
(-) OUT
STYLE D OPTIONAL WIRING
System wiring diagram for 2-wire duct detectors (detectors powered from initiating circuit)
V In + V In / V Out -
7 8
DH100 Test + Test / Reset - Reset + RA + RA - V Out + V In + V In / V Out - 1 2 3 4 5 6 7 8 Panel + - 5
RTS451 KEY Test 4 3 1 2 6 No Connection Alarm LED Reset
Wiring diagram for RTS451/RTS451KEY Remote Test Station to 2-wire duct detectors
Page 3
A05-976-00
Ordering Information
Part No. DH100I DH100P A5052-00 A5069-00 A5061-00 Accessories ST-1.5 ST-3 ST-5 ST-10 T80-71-00 P48-55-00 Description 2-wire ionization duct detector 2-wire photoelectronic duct detector Replacement ionization sensor board Replacement photoelectronic sensor board 2-wire power board Metal sampling tube duct widths 1-2 Metal sampling tube duct widths 2-4 Metal sampling tube duct widths 4-8 Metal sampling tube duct widths 8-12 Telescoping sampling tube End cap for T80-71-00 RTS451KEY RTS451 RA400Z APA451 MOD400R F36-09-00 M02-04-00 P48-21-00 S08-39-01 PA400B PS24LOB PS12/24LENSC PS12/24LENSW Remote test station with key lock Remote test station Remote annunciator alarm LED Remote annunciator with piezo alarm Sensitivity test module Replacement air filters (two per package) Test magnet End cap for metal sampling tubes Photo replacement screen Mini-Alert sounder Mini-Alert add-on strobe Ceiling-mount "SMOKE" lens Wall-mount "SMOKE" lens
Accessories
System Sensor provides system flexibility with a variety of accessories, including two remote test stations, and several different means of visible and audible system annunciation. As with our duct detectors, all duct detector accessories are UL listed.
ALARM
ALARM
POWER
RESET
ON
TEST
F I R E
PA400 with PS24LOW Add-on Strobe (PS12/24LENSW smoke lens option available) (UL S3593)
ALARM
RESET
APA451 Piezo Annunciator (UL S4011)
RTS451KEY Remote Test Station with Key (UL S2522)
RTS451 Remote Test Station (UL S2522)
RA400Z Remote Annunciator (UL S2522)
System Sensor Worldwide Manufacturing & Distribution
In Canada: Telephone: 905-812-0767 Fax: 905-812-0771 In China: Telephone: 852-2191-9003 Fax: 852-2736-6580 Page 4 In the Far East: Telephone: 852-2191-9003 Fax: 852-2736-6580 In India: Telefax: 91-022-8202564 In Italy: Telephone: 39-40-9490-111 Fax: 39-40-382137 In Singapore: Telephone: 65-273-2230 Fax: 65-273-2610 A05-976-00 In the United Kingdom: Telephone: 44-1403-276500 Fax: 44-1403-276501


▲Up To Search▲   

 
Price & Availability of A5061-00

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X